OCM-036 unica
Rotor Machine
Main features
- Reduced size and weight
- Ease of use
- Wet and dry sprayed concrete applications
- Hydraulic rotor closing system
- Lubricated sealing gasket
- Robust and reliable
- Also available in fully pneumatic and DOSA versions
MACHINE FOR WET AND DRY SPRAYED CONCRETE LININGS
It features the same pumping groups and hoses’ section as the economical OCM-035 L SIMPLEX version. Like the latter, it can be used for wet and dry sprayed concrete applications with effective outputs of up to 5 M3/h.
Easy to use, robust, compact and manoeuvrable, it finds its typical field of application in foundation and soil consolidation works, restoration of damaged structures, medium/small section tunnels, typically in hydroelectric projects or in the mining sector. Finally, it can also be used in the pneumatic conveyance of crushed stone, expanded clay and granular materials in general.
The OCM-036 UNICA features the exclusive hydraulic clamping system of the rubber sealing gaskets on the rotor, which allows you to optimize the wear of gaskets and rotor plates, besides allowing its use even in extreme conditions. Recommended when low slump wet mixes have to be sprayed or when large distances have to be reached. In such cases, in fact, the effective hydraulic sealing of the rotor allows to better compensate the high pressures that develop inside the pipe.
Finally, like all Ocmer rotor machines, the OCM-036 UNICA can also be supplied complete with high pressure water pump, wired or radio remote control, dosing unit for the liquid quick setting chemical admixtures (DOSA version) and module for recording and transmitting the main production parameters.
Weights 590-720 Kg
(* PROVIDED THE CHAMBERS FILL AND EMPTY COMPLETELY)
Electric Drive
-
Installed power: from 4.5 to 6,5 Kw (varies depending on the options required), 3 x 400 V 50/60 Hz (other voltages on request)
-
Effective flow rate: 1 to 5 M3/h
-
Compressed air consumption: from 6.000 to 15.000 litres/m at 7-8 bars
- Electrical panel: compliant with EEC standards (EN-60204-1; EN-60439-1; 73/23 EEC; 98/68/EEC); IP55 protection rating Degree of protection: IP 55
Pneumatic Drive
- Main Engine: KW 6,6
- Hydraulic power unit motor power: KW 2.96
- Air consumption: 9.000 litres/m at 7-8 bars
Do you want more information or have any requests? Fill out the form alongside with your information and questions. Our team will be happy to help you and will contact you as soon as possible!
Address
OCMER Co. srl – Partita IVA: IT08959020150
Via 1° Maggio, 33, 20014 Nerviano (MI) Italy
Phone
+39 0331 415221